Due to the high volume of orders, orders may be processed with a slight delay

Search

Need help? NL +31(0)6 84 74 10 51 / PL +48 793 194 307
Need help? NL +31(0)6 84 74 10 51 / PL +48 793 194 307

In Stock

Crepe Paper

Crepe Paper is product that can be used for wrapping materials to be sterilized in steam, Ethylen Oxide and Formaldehyde (FO). Our products which are manifactured with different lenght and weight based on the demands of users, provide significant convenience for the users in the sterilization units. Crepe Papers can be produced in blue and green colors.

<span class="ts-tooltip button-tooltip" data-title="Add to compare">Compare</span>
SKU:Product Code: 4ADXR06

TECHNICAL DATA SHEET

CREPE PAPER (Green, Blue)

PRODUCT CODE: 4ACP

RELATED STANDARDS: 4A branded crepe papers are in compliance with the provisions of the Medical Device Regulation 2017/745 for medical devices.

INTENDED USE: Sterility assurance is a critical cornerstone of effective patient care. Therefore, the medical device wrapping is a very important step of the sterilization process. Suitable wrapping techniques and proper wrapping material use provide a sterile barrier during and after the sterilization process. 4A Crepe paper is used to wrap materials to be sterilized like trays, surgical kits. Crepe paper is preferred instead of fabric due to the smaller pore structures.

OPERATION CONDITIONS: 4A Crepe papers are used for steam, ethylene oxide, formaldehyde and gamma irradiation sterilization methods. The sterilization conditions should be determined by the end user regarding the material to be sterilized.

SPECIFICATIONS:

SPECIFICATIONUNITTYPICAL VALUE
SUBSTANCE60.6
THICKNESSmicron141.00
TENSILE STRENGHT MD21.3
TENSILE STRENGHT CD17.1
WET STRENGHT MD6.8
WET STRENGHT CD5.2
BREAKING LENGTH MDkm2.4
BREAKING LENGTH CDkm1.8
STRETCH MD9.2
BURST STRENGHTkPa117
AIR PERMEABILITY4581
WATER ABSORBENCY23
pH6.3
Absolute moisture content5.6

STORAGE AND DISPOSAL: It must be boxed with polyethylene bags in as much as it shall not be damaged by external factors during storage and shipment. It must be kept away from toxic substances. The date of manufacturing and expiry date are stated on the outer packing. Shelf life is 5 years after the production date.

PACKAGING:

DimensionsPieces in carton
500
500
250
250
250
250

MANUFACTURER:

DORT-A TIP MALZEMELERI SAN. ITH. IHR. TIC. LTD. STI. Balıkhisar Mahallesi, Köyiçi Serpmeleri, No:795 Akyurt, Ankara, Turkey Tel: +90 312 363 50 52/53 Fax: +90 312 363 52 10 Web: http://www.4amedical.com

Product CodeProduct NameQTYSize
4ACP3003001x300 mmx300mm
4ACP4004001x400 mm x400 mm
4ACP5005001x500 mm x500 mm
4ACP6006001x600 mm x600 mm
4ACP7507501x750 mm x750 mm
4ACP0009001x900 mm x900 mm
4ACP100010001x1000 mm x1000 mm
4ACP120012001x1200 mm x1200 mm

Reviews

There are no reviews yet.

Write a review

Your email address will not be published. Required fields are marked *

Bestsellers

Product Code: 4ADXR13

Bowie Dick Test Pack

(0 Reviews)
  • Data Sheet
Bowie Dick Test Packs are the testing packages that should be used before starting daily machine sterilization process for steam sterilization devices. Bowie Dick Test Pack is used for the purpose of testing whether there is air leakage and efficient steam penetration in the steam sterilizers. Bowie Dick Test Packs color change allows assurance of whether the steam sterilizers are ready for the sterilization or not. Different kinds of Bowie Dick Test Packs are available These are Bowie Dick Test Pack 200 (wrapped in medical paper, wrapped in crepe paper and BD in box), Bowie Dick Test Pack 400 (wrapped in medical paper and wrapped in crepe paper) and Bowie Dick Test Pack EWS (Early
Product Code: 4ACF

Container Filter

(0 Reviews)
    • Data Sheet
    • 4ACF
Container Filters are soft and porous single use medical grade paper filters used with sterilization containers in clinics and hospitals for sterilization by autoclaving of instruments and other materials for surgical use. They are suitable with all types of containers and baskets. Container Filters are placed in the lid and body of the sterilization container to allow steam penetration during sterilization and to maintain sterility post sterilization. Circular shape container filters and rectangular shape container filters. Rectangular shape container filters have assortments of 120mm x 230mm and 165mm x 230mm.
Product Code: 4ASBI

Steam Biological Indicator

(0 Reviews)
  • Data Sheet
  • 4AEOBI
Biological indicators are test systems containing viable microorganisms providing a defined resistance to a specific sterilization process. A biological indicator provides information on whether necessary conditions were met to kill a specified number of microorganisms for a given sterilization process, providing a level of confidence in the process. Steam Biological Indicator (3h and 24h) is specifically designed for the monitoring steam sterilization processes at 121 – 134 °C. The final readout of a processed biological indicator with respect to the indicator type should be made after 3 hours (4ARSBI) or 24h (4ASBI) of incubation at 60+/- 2 °C.
Product Code: 4ADXR17

Sterilization Gusset Pouches

(0 Reviews)
  • Data Sheet
Medical Paper provides maximum safety. Pouches constructed from high grade medical kraft paper and multilayer transparent co-polymer film.Strong seal strength. Superior barrier and quality with 60gsm or 70gsm medical kraft paper.Indicators which are water based , non toxic and give accurate result for steam, EO Gas and Formaldehyde (FO) Strong seal-strength, visible sealing lines.Clean fibre-free opening.All materials comply with international standards. Opening direction marked.Conformity with EN 868-5. Gusset pouches have more internal volume comparing to flat pouches owing to the special design of the co-polymer film.Apart from those standard sizes, as long as the width is one of the standards, there is no limit at lengths. Gusset Pouches are packed as 100 pieces wrapped in film according to requested dimension.Note: Sterilization Bags can be produced with your trademark.
Product Code: 4ADXR13-1

PCD & Helix

(0 Reviews)
  • Data Sheet
PCD- Helix Load Control Test has a self adhesive indicator on the far end. The PCD test kit has a 1 m long hose, and the Helix test kit has a 1.5 m long hose. There are 100 indicators in each package. In this product used for load control, the adhesive indicator is placed at the far end of the test apparatus, steam inlet only can be at the beginning of the hose and it can reach the chemical indicator at the end of the hose by passing at a single point. If the chemical indicator color change is achieved despite the difficult conditions, it is an important reference for the sterilization process in that load and should be recorded as a record for the successful sterilization of the load.
Product Code: 4ACL

Container Label

(0 Reviews)
  • Data Sheet
  • 4ASSI
Security Seals are used in order to secure the container for opening by un-authorized staff. Container can be opened only by breaking the seal. Security seals are guaranteeing the sterility of materials from the moment of sterilization till the actual use.
Product Code: 4AIP

Incubator 37C/59C

(0 Reviews)
  • Data Sheet
  • 4AIP
4A Medical Incubator is designed to incubate 4ASBI (24 hours) steam biological indicators for steam sterilization process, 4AEOBI Ethylene Oxide biological indicators for EO sterilization process and 4APBI plasma biological indicators for Hydrogen Peroxide sterilization process. Incubation temperatures vary depending on the indicator, because the microorganisms included within the Biological Indicators differentiate based on the sterilizing method for which they were created. Three incubation programs are available: MOD 1 – 48 hours at 370C for EO biological indicators, MOD 2 – 24 hours at 570C for steam biological indicators and MOD 3 – 24 hours at 600C for plasma biological indicators. The incubator makes it simple to identify positive and negative results for Biological Indicators. If the sterilization success is negative, the color of the culture media turns yellow. The color change should be interpreted that the sterilization was not successful.
Back to Top